ESD footwears are the first line of defence against electrostatic charge build up on the human body. They are designed to drain away this charge to ground, as soon as it is generated. At the same time the special footwear must remain electrically safe for the user. Thus, it is important to test every footwear regularly.
In order to protect sensitive electronic components, the maximum footwear resistance should not be more than 35 meg ohms. On the other hand, the resistance should not be less than 0.75 Mohm as protection to the wearer from dangerous levels of voltage and current flow.
This DUAL footwear tester checks these parameters under actual operating conditions while wearing the footwear. The unique DUAL testing circuits ensure that both Left and Right side ESD footwear are tested independantly.
SPECIFICATIONS
| Pass Range |
0.75 meg ohms to 35.0 meg ohm. |
| (seperate for left & right) |
Fail (low - RED LED Fail (High) - RED LED Audible Alarm for Fail mode. |
| Indications |
Pass - GREEN LED |
| Actuation |
By gently pressing metal sensor plate. |
| Accuracy |
+ 10% |
| Power requirement |
9 V DC battery. |
| Low Battery |
Orange - Warning less than 7 volts. |
| Dimensions |
(instrument) 125 x 75 x 29 mm.
(stand) 51 x 46 x 97 mm ht. |
| Weight |
(instrument) 200 grams (stand) 5.5 Kgs |
| Calibration |
Recommended every 12 months. |
| Traceability |
To national standards |
| Warranty |
12 months. |

|